Technical Information

Detailed technical data for QuadCore KS1000RW Roof Panels, including thermal performance, fire classification, air tightness, and acoustic properties.

Available Lengths
Available Lengths
Standard lengthsLonger lengths (non-standard)Shorter lengths (non-standard)
1.8 - 14.5 m14.5 - 29.2 mBelow 1.8 m

Note: Additional costs and transport restrictions may apply for non-standard lengths. All lengths may change for export (outside of the UK & Ireland).

Dimensions, Weight & Thermal Performance
Dimensions, Weight & Thermal Performance
Core Thickness (mm)405360738091100115120137150167
Overall Thickness (mm)718491104111122131146151168181198
U-value (W/m²K)0.470.350.310.250.230.200.180.160.150.130.120.11
Weight (kg/m²)9.09.59.710.210.510.911.311.812.012.713.213.8

The QuadCore insulation used in QuadCore KS1000RW Roof Panels have a Thermal Conductivity (λ) of 0.018W/m.K

QuadCore KS1000RW Roof Panels have a Thermal Transmittance (U-Value), calculated using the method required by the Building Regulations Part L2 (England & Wales), Building Standards Section 6 (Scotland), Part L (Republic of Ireland) and Part F2 (Northern Ireland).

Certification and Testing

Reaction to Fire

QuadCore KS1000RW Roof Panels are classified B-s1,d0, when tested on the internal face of the product, according to the European Reaction to Fire classification system (Euroclasses) BS EN 13501-1: 2018 under the certified name QuadCore KS1000RW when using the following internal liners: CLEANsafe 15, CLEANsafe 25, CLEANsafe 55, CLEANsafe 120 and AQUAsafe 55. Please contact Kingspan Tech-eXchange for information relating to the external face.

Roof Applications

QuadCore KS1000RW Roof Panels are tested to:

Broof(t4) to BS EN 13501-5: 2016 under the certified name KS1000RW for panel thicknesses 40 - 167mm and roof pitch of 0° - 10°. Broof(t4) to BS EN 13501-5: 2016 under the certified name KS1000RW for panel thicknesses 40 - 167mm and roof pitch of >10°.

Fire Resistance

Fire resistance classifications are subject to panel thickness, orientation, method of assembly, and steel coating. Please contact Kingspan Tech-eXchange for project specific details.

Insurer Approvals

QuadCore KS1000RW Roof Panels are tested to:

LPS 1181 Part 1: Issue 1.2 Requirements and tests for built-up cladding and sandwich panel systems for use as the external envelope of buildings certified to:

–LPS 1181-1 Grade EXT-B under the certified name QuadCore KS1000RW (Roof Panel) for thicknesses 40 - 150mm.

FM 4471 approval standard for class 1 roof panels under the certified name KS1000 RW for thicknesses 40 – 167mm.

FM 4880 approval standard for class 1 fire rating of building panels or interior finish materials under the certified name KS1000RW for thicknesses 40 - 167mm.

FM 4882 approval standard for class 1 interior wall and ceiling materials or systems for smoke sensitive occupancies under the certified name KS1000RW for thicknesses 40 - 167mm.

Insurer approvals are large scale testing regimes that provide objective third-party testing, which is underpinned by quarterly, bi-annual and annual factory surveillance audits (depending on the region) to verify compliance. Insurer approvals are subject to panel thickness, cover width, orientation, method of assembly, steel coating and manufacturing facility. Please contact Kingspan Tech-eXchange for further information.

FM LPCB Approval Marks
Air Leakage

An air leakage rate of 3m³/hr/m² at 50Pa or less can be achieved when using Kingspan insulated roof and wall panels. For information on detailing required to achieve lower air leakage rates, please contact Kingspan Tech-eXchange.

Acoustic

* Frequency

QuadCore KS1000RW Roof Panels have a single figure weighted sound reduction Rw = 25dB. Results are based on panels of similar profile and core material.

Sound Reduction Index (SRI)
Hz*631252505001K2K4K8K
SRI2018202420293947

* Frequency

QuadCore KS1000RW Roof Panels have a single figure weighted sound reduction Rw = 25dB. Results are based on panels of similar profile and core material.

Product Tolerance
Product Tolerance
Cut to Length±5 mm
Cover Width±2 mm
Thickness (Core ≤ 100 mm)±2 mm
Thickness (Core > 100 mm)±2%
End Square±3 mm
Warranty

QuadCore Assured Panel Warranty

25 years thermal performance

25 years fire performance

25 years structural performance

25 years environmental performance

Up to 40 years coating performance

NBS Specification

View QuadCore KS1000RW Roof Panel on NBS Source.

Downloads

Access product brochures, datasheets, and technical documentation to support specification and project planning.

Viewing 1-6 of 11 downloads
kingspan-quadcore-ks1000rw-roof-panel-data-sheet-en-gb-ie.pdf

QuadCore KS1000RW Roof Panel Data Sheet

Data Sheets
Download
kingspan-quadcore-lec-ks1000rw-roof-panel-data-sheet-en-gb-ie.pdf

QuadCore KS1000RW LEC Roof Panel Data Sheet

Data Sheets
Download
kingspan-colours-and-coatings-brochure-en-gb-ie

Colours & Coatings Brochure

Brochures
Download
kingspan-quadcore-ks1000rw-roof-panel-construction-detail-en-gb-ie.pdf

Construction Details PDF

Technical Drawings
Download
kingspan-quadcore-ks1000rw-roof-panel-construction-detail-en-gb-ie.dwg

Construction Details DWG

Technical Drawings
Download
kingspan-quadcore-ks1000rw-declaration-of-performance-en-gb-ie.pdf

Declaration of Performance

Declaration of Performance (DoP)
Download
Viewing 1-6 of 11 downloads

Complementary Products

Explore our complementary systems and solutions designed to complete your buildings envelope.

Quadcore Coldstore Wall Panel

QuadCore Coldstore Wall Panel

Insulated sandwich panels for temperature-controlled buildings

Quadcore AWP Wall Panel

QuadCore AWP Wall Panel

Insulated architectural wall panel designed for flexibility and efficiency

quadcore ks1000rw wall panel render

QuadCore KS1000RW Wall Panel

High-performance trapezoidal insulated wall panel with an industrial look

Quadcore Powerpanel Render

Quadcore PowerPanel

PowerPanel combines high-performance QuadCore thermal efficiency and leading photovoltaic technology.

Case Studies

Related Projects

See how QuadCore KS1000RW Roof Panels are used in real projects across commercial and industrial sectors

Commercial unit

Blackpool Enterprise Zone

Contributing towards energy efficiency and sustainability in a major new northwest hub.

Distillery

Dalmunach Distillery

The construction of this new Speyside malt whiskey distillery is the result of increasing global demand for scotch whiskey.

Industrial building

AST Signs

An ultra-modern, purpose-built headquarters and manufacturing hub for AST signs.

Supermarket

Aldi Whitchurch

A full envelope solution for a new Aldi supermarket, helping it to be delivered in challenging times.

Car dealership

Hendy Group

Hendy Group achieves BREEAM Excellent through cutting-edge sustainable solutions.